Testing hydraulic and flows characteristics.
Principal stations:
Test bench for checking fuel collector flows:
- max. pressure - 10 Mpa
- max. flow - 12000 l/h
Fuel injectors' test bench:
- max. pressure - 10 MPa
- outlay - 2000 l/h
Afterburner fuel pump test bench:
- power drive - 285 KW
- propeller shaft rotational speed range - 0-30000 r.p.m.
High pressure fuel pumps test bench:
- power drive - 125 KW
- propeller shaft rotational speed - 4150 r.p.m.
- max. pressure - 21 MPa
Main fuel pumps test bench:
- power drive - 110 kW
- propeller shaft rotational speed - 4150 r.p.m.
Engine nozzles controllers' test bench:
- max. pressure - 8 MPa
- max. flow - 25000 l/h
Combustor and afterburner starters test bench:
- feeding power - 390 kW
- active factors: fuel, oxygen, air
- fuel pressure 6 MPa, oxygen pressure 1,6 MPa, air pressure 2,3 MPa
Oil units test bench:
- power drive - 73 kW
- drive rotational speed - 11800 r.p.m.
|